There are many combinations and set ups that will work for electric powered aircraft.  Here are some formulas that will make it easy for you to determine what the proper set up will be for a jet.

To calculate your fan rpm's: Take the voltage of the battery and multiply the KV of the motor = Fan RPM
                                                                   11.1v X 3600= 39,960 rpm.

To calculate what KV motor you need: Take the desired fan RPM divide it by the battery voltage= Needed Motor KV
                                                                   45,000/ 14.8v=3040kv motor.

To calculate what battery you need: Take desired fan RPM divide it by the motor kv = Battery Size
                                                                   45,000/ 3600kv=12.5v (3 cell).

To calculate approximate amps drawn: Take watts divide it by the volts = Amps
                                                                   800 watts/ 14.8v=54amps.

To calculate volts needed: Take watts divide it by the amps = volts
                                                                   450 watts/ 40amps= 11.25volts.

To calculate watts: Take amps multiply it by volts = Watts
                                                                   57amps X 14.8v= 843watts.

These are approximate numbers depending on efficiency, quality of connections, and resistance, but this guide line will help determine what set up to use with electrics.  The data below are estimations based on the above formulas and information provided by the manufacturer.  Fan Jets USA is not responsible for changes in the specifications of the motors by the manufacturer.


The following are recommended setups for edf units based on fan rpm's. The higher the fan rpm, the faster the jet.  The 90mm edf's are designed to operate from 30,000 to 47,000 rpm. Speeds vary based on the weight and aerodynamics of the jet. The 120mm edf units are desinged to operate around 24,000 to 38,000 rpm. Any thing above this, may exceed the manufacturers recommendations.  Speeds vary based on the weight and aerodynamics of the jet. 

Be sure to use a watt meter when programming the power system to check watt and amp draw.  This can be limited by adjusting the throttle  epa's.  Going up in blade count will have an impact on watt and amp draw.  Generally a lower kv motor should be used on edf's that have higher blade counts.

COLOR CODE (Estimations): ORANGE= MILD SETUP (60 TO 90 MPH)
                                       
GREEN= MODERATE SETUP (90 TO 120 MPH)
                                            RED= WILD SETUP (120 PLUS MPH)



FAN RPM

MOTOR: 90MM CLASS

LI-PO BATTERY:
25C OR HIGER

 SPEED CONTROL

41,440

51,800

ARC 36-55-1

4 CELL

5 CELL

100 AMP

100 AMP

34,225

41,070

47,915

ARC 36-55-1.5

5 CELL

6 CELL

7 CELL

100 AMP

100 AMP

75 AMP

41,440
46,620
51,800

ARC 36-55-2

8 CELL
9 CELL
10 CELL

75 AMP

85HV AMP

85HV AMP

38,480
46,176

ARC 36-65-1

5 CELL
6 CELL

120 AMP

120 AMP

37,296
43,512
49,728

ARC 36-75-1

6 CELL
7 CELL
8 CELL

100 AMP

85HV AMP

85HV AMP

41,810
45,991
50,172

ARC 36-75-1.5

10 CELL
11 CELL
12 CELL

85HV AMP

85HV AMP

85HV AMP

33,300

HET 600-22

3 CELL

75 AMP

37,000

HET 600-32

5 CELL

60 AMP

35,520
41,400
47,360

HET 600-42

6 CELL
7 CELL
8 CELL

70 AMP
60 AMP
55 AMP

40,700
44,700
48,840

HET 600-43

10 CELL
11 CELL
12 CELL

50 HV AMP
50 HV AMP
50 HV AMP

41,810

45,991

50,172

HET 650-68-1130

10 CELL

11 CELL

12 CELL

80HV AMP

80HV AMP

80HV AMP

49,580

54,538

59,496

HET 650-68-1340

10 CELL

11 CELL

12 CELL

110HV AMP

110HV AMP

110HV AMP

44,400

49,950

55,500

HET 650-68-1500

8 CELL

9 CELL

10 CELL

120HV AMP

120HV AMP

120HV AMP

47,360

HET 650-68-1600

8 CELL

100 AMP

41,625

49,950

HET 650-68-2250

5 CELL

6 CELL

120 AMP

120 AMP

39,516

49.395

HET 650-68-2670

4 CELL

5 CELL

130 AMP

120 AMP

38,461
43,956
49,450
55,093

HET 700-60-1485 

7 CELL
8 CELL
9 CELL
10 CELL 

ICE 50 AMP
ICE 50 AMP
45HV AMP
45HV AMP

34,502
41,403
48,303
55,204

HET 700-60-1865 

5 CELL
6 CELL
7 CELL

8 CELL

65 AMP
60 AMP
50 AMP

50 AMP

38,943

46,287

54,001

61,716

HET 700-60-2085

5 CELL

6 CELL

7 CELL

8 CELL

70 AMP

70 AMP

60 AMP

60 AMP

38,628
48,285
57,942

HET 700-60-2610 

4 CELL
5 CELL
6 CELL

80 AMP
70 AMP
60 AMP

35,520

39,960

44,400

48,800

53,280

HET 700-68-1200

8 CELL

9 CELL

10 CELL

11 CELL

12 CELL

50HV AMP

50HV AMP

50HV AMP

50HV AMP

50HV AMP

38,850
44,400
49,950

55,000 

HET 700-68-1500 

7 CELL
8 CELL
9 CELL
10 CELL

60 AMP
50 AMP
50 HV AMP
50 HV AMP

37,296
43,512
49,728
55,944

HET 700-68-1680 

6 CELL
7 CELL
8 CELL
9 CELL

65 AMP
60 AMP
50 AMP
50HV AMP

41,625
49,950
58,275

HET 700-68-2250 

5 CELL
6 CELL
7 CELL

80 AMP
70 AMP
60 AMP

41,440
51,800
62,160

HET 700-68-2800 

4 CELL
5 CELL
6 CELL

100 AMP
80 AMP
70 AMP

49,025

58,830

LEOPARD LBP3674/2.5D

5 CELL

6 CELL

110 AMP

110 AMP

40,700

48,840

56,980

LEOPARD LBP3674/3D

5 CELL

6 CELL

7 CELL

90 AMP

90 AMP

90 AMP

35,150

42,218

49,210

56,240

LEOPARD LBP3674/3.5D

5 CELL

6 CELL

7 CELL

8 CELL

80 AMP

80 AMP

80 AMP

80 AMP

35,964

RC LANDER 90MM 1620KV

12 BLADE EDF

6 CELL

110 AMP

29,600

33,300

37,000

RC LANDER 90MM 1000KV

12 BLADE EDF

8 CELL

9 CELL

10 CELL

100 AMP

110 AMP

110 AMP

36,852

RC LANDER 90MM
1620kv 12 BLADE DPS

6 CELL

100 AMP

42,180

RC Lander 90MM
1900kv DYNAMIC POWER SERIES 

6 CELL

70 AMP

37,888

RC LANDER 90MM
1280kv METAL FAN

8 CELL

70 AMP

41,440 

RC Lander 90mm
1400kv 12 BLADE DPS 

8 CELL

115 AMP

29,600

33,300

37,000

RC Lander 90 MM
1000kv 12 BLADE DPS

8 CELL

9 CELL

10 CELL

110 AMP

110 AMP

110 AMP



RPM  120MM CLASS  LIPO BATTERY:
25C OR HIGER 
 SPEED CONTROL
36,075
39,682
43,290
HET 700-83-975 10 CELL
11 CELL
12 CELL
60HV AMP
60HV AMP
60HV AMP
39,960
43,956

47,952
HET 700-83-1080  10 CELL
11 CELL

12 CELL
60HV AMP
60HV AMP
60HV AMP
37,425
42,772

48,118
53,465
HET 700-83-1445 7 CELL
8 CELL
9 CELL
10 CELL
80HV
80HV
80HV
80HV
29,748
32,227
34,706
HET 700-98-670  12 CELL
13 CELL
14 CELL
60HV AMP
60HV AMP
60HV AMP
30,710
33,781
36,852
HET 700-98-830 10 CELL
11 CELL
12 CELL
80HV
80HV
80HV
43,512 RC LANDER 980KV
METAL FAN UNIT 
12 CELL 110HV
90 MM
MOTOR

DIAMETER

LENGTH SHAFT
DIAM.
BATTERY
(LI-PO)
NO LOAD
CURRENT (IO)
INTERNAL
RESISTANCE
KV MAX
CURRENT
NOMINAL
POWER
ARC
36-55-1 
36 MM  55 MM  5 MM  4-5S  NA  NA   2800KV NA  NA 
 ARC
36-55-1.5
36 MM  55 MM  5 MM  5-7S  NA  NA  1850KV  NA  NA 
ARC
36-55-2
36 MM 55 MM 5 MM 8-10S  NA NA 1400KV  NA  NA
ARC
36-65-1
 36 MM 65 MM   5 MM 5-6S  NA  NA  2080KV  NA  NA 
ARC
36-75-1
36 MM 75 MM 5 MM 6-8S  NA  NA 1680KV  NA  NA
ARC
36-75-1.5
36 MM 75 MM 5 MM 10-12S  NA NA  11300KV  NA 1000 WATTS 
HET
600-22
36 MM 60 MM 5 MM 3S 2.6 13 3000KV 70A 600
WATTS
HET
600-32
36 MM 70 MM 5 MM 5S 2.0 16 2050KV 70A 800
WATTS
HET
600-42
36 MM 85 MM 5 MM 6-8S 1.6 23 1600KV 80A 1200
WATTS
HET
600-43
36 MM 85 MM 5 MM 10-12S 0.8 46 1100KV 80A 1400
WATTS
HET
700-60-1485
39MM 60 MM 5 MM 7-10S 1.4 15  1485KV 70A 1200
WATTS
HET
700-60-1865
39 MM 60 MM 5 MM 5-8S 8.7 14 1865KV 75A 1200 WATTS
HET
700-60-2610
39 MM 60 MM 5 MM 4-6S 2.7 5.7 2610KV 80A 1200 WATTS
HET
700-68-1200
 
39 MM  68 MM  5 MM  8-12S  1.3  12   1200KV  80 A 1400
WATTS 
HET
700-68-1500
39 MM 68 MM 5 MM 7-10S 1.5 9.9 1500KV 125A 1400
WATTS
HET
700-68-1680
39 MM 68 MM 5 MM 6-9S 1.9 8.9 1680  70A 1400
 HET
700-68-2250
39 MM   68 MM  5 MM 5-7S  2.2  4.6  2250  95A   1400
HET
700-68-2800
39 MM 68 MM 5 MM 4-6S 3.0 3.5 2800KV 170A 1400 WATTS
RC LANDER
6S METAL FAN
NA NA 5MM 6S 2.5 NA 1660KV 75A NA
RC Lander 6S
Dynamic Power
NA NA 5MM 6S NA NA 1900KV 80A 1500
WATTS
RC LANDER
8S METAL FAN
NA NA 5MM 8S NA NA 1280KV 75A NA
 RC LANDER 9S DYNAMIC POWER NA  NA  5MM  9S NA   NA 1290KV  95A  1500
WATTS
 
RC Lander 10S
Dynamic Power
NA NA 5MM 10S NA NA 1290KV 85A 2600
WATTS

120MM
MOTOR

DIAMETER   LENGTH  SHAFT
DIA
BATTERY
(LIPO)
 NO LOAD
CURRENT (IO)
 INTERNAL
RESISTANCE
 KV  MAX
CURRENT
 NOMINAL
POWER
HET
700-83-1445
 
39MM 82.8MM 5 OR 8MM 7-10S 3.2A
(12V)
6.8 1445KV 80HV 1600
WATTS
HET
700-98-830 
 39MM 98MM 8MM 10-12S 1.6A
(12V)
11.20  830KV 80HV  2400
WATTS
RC LANDER 120MM
METAL FAN
 
NA NA 5MM 12S NA NA 980KV 120A NA
Website Builder